Log in to HSS DIY today to track your deliveries, extend your hire and check out faster, all in one place.

Log in to HSS DIY today to track your deliveries, extend your hire and check out faster, all in one place.

Log in to HSS DIY today to track your deliveries, extend your hire and check out faster, all in one place.

Log in to HSS DIY today to track your deliveries, extend your hire and check out faster, all in one place.

Log in to HSS DIY today to track your deliveries, extend your hire and check out faster, all in one place.

HSS DIY home

Browse

Hire a generator for additional power from HSS DIY

Written by: 

Date: 

Categories: , Power, Generators, Tips & Advice - Power

A portable petrol generator running outdoors beside a UK home, available to hire from HSS DIY

⏱ Read time: 10 min | 🌿 Difficulty: Beginner | ⏰ Time: 10 minutes to work out your load | 👷 1 person (2 or delivery for the diesels)

Quick answer. Choose a generator based on what you need to power, not the biggest machine available. Add up the running load in kVA of everything you'll use at once, allow for start-up loads, add 20–25% headroom and match the voltage. HSS DIY hires petrol and silenced diesel generators from 1.6kVA to 10kVA online, with site generators up to 100kVA on request. Click and collect from a local HSS DIY partner branch or have your generator delivered.

Range 1.6kVA–10kVA online, larger on request · Petrol and diesel · 3–16 hours per tank · Delivery in 24–48h, or click & collect

Check what size generator you need

Petrol and diesel generators lined up ready for hire

Key takeaways

  • Compare your total load with a generator's continuous kVA rating, not its headline size.
  • Motors can draw two to three times their running load when they start.
  • Petrol generators fit in an estate car; the 6kVA and 10kVA diesels need a 7.5-tonne vehicle or delivery.
  • Fuel isn't included, and generators must only ever run outdoors.
  • Above about 10kVA, or for three-phase power, ask HSS or a qualified electrician to check your loads.

Table of contents

  1. Generators to hire
  2. What size generator do I need?
  3. Generator hire for different applications
  4. Generator capacity and power output
  5. Fuel consumption and runtime
  6. How much does it cost to hire a generator?
  7. Generator delivery and collection
  8. Generator safety
  9. FAQs
  10. Ready to hire a generator?

Generators to hire

Hire petrol and silenced diesel generators from HSS DIY for construction sites, events, outdoor projects and emergency or temporary power. We have a range of generators that can power anything from small tools to all-day events.

Generator
Output
Fuel
Sockets · noise · weight
Tank / runtime
Suits
From (inc. VAT)*
Portable 2.6kVA Petrol
2.2kVA cont.
Petrol
110V/240V · not silenced · 41kg
3L · 3h at ¾ load
Lighting, small power tools
£28.76
Generator 3kVA Petrol
Up to 3kVA
Petrol
110V/240V · not silenced · compact
-
General trade tools
£49.58
Generator 4kVA Petrol
3.2kVA cont.
Petrol
110V/240V, 16A/32A · not silenced · 63kg
3L · 3h over 3kVA
Several tools, site lighting
£63.84
Suitcase 1.6kVA Petrol
1.6kVA cont.
Petrol
110V only · suitcase · 21kg
4L · up to 7h
110V tools up to 2kVA
£75.95
6kVA Silenced Diesel
4.3kVA cont.
Diesel
3×230V, 3×110V · 93dB · 195kg
24L · up to 16h
All-day site, events, emergency
£77.99
10kVA Silenced Diesel
7.2kVA cont.
Diesel
3×230V, 4×110V · 96dBA · 365kg
15L · up to 10h
Multiple users, cabins
£121.34
Larger site generators
20–100kVA+
Diesel
Single and 3-phase
—
Compounds, large events, standby
Quote
*Prices checked November 2026, shown inc. VAT. Check live generator pages for current prices.

What size generator do I need?

The right generator is the one that comfortably powers what you need, not the biggest machine available. Choosing an oversized generator costs more to hire and burns more fuel than you need to. To find the right size:

  1. List everything that will run at the same time and note each item’s running load in kVA. Rating plates often show this in watts, so divide by 1,000 to get an approximate kVA figure.
  2. Allow for starting loads, as equipment with a motor, such as saws, compressors, pumps and fridges, can briefly draw two to three times its running load when it first starts up.
  3. Add 20–25% headroom on top of your total, so the generator isn’t running flat out all day.
  4. Match the voltage to your equipment. Site tools usually run on 110V and household appliances on 230V, so bear in mind that the 1.6kVA suitcase generator is 110V only.
  5. Think about how long you’ll need power for. For long days or overnight running, a diesel generator’s bigger tank and lower noise often make it a better choice than petrol.

Reading generator sizes: every generator on this page is rated in kVA, but it’s the continuous rating you need to compare with your total load, not the headline size. For example, the 10kVA silenced diesel delivers 7.2kVA continuously, so that’s the figure to work to.

Portable petrol generators lined up in a yard ready for hire

Generator hire for different applications

When you're hiring a generator, make sure it's powerful enough for what you need it for.

Generator capacity and power output

The table below shows what each size of generator can typically power, from a single tool to a whole construction compound. Use the continuous output column to compare against your total load, as that’s the power the generator can deliver all day, not just its headline size.

Capacity
Continuous output
Typically suits
HSS options
1.6–3kVA portable
1.6–3.0kVA
Single tools, lighting, chargers
1.6kVA suitcase (110V), 2.6kVA, 3kVA petrol
4kVA
3.2kVA
Several tools at once, heavier-draw tools
Generator 4kVA petrol
6–10kVA silenced
4.3–7.2kVA
All-day site use, small events, multiple users
6kVA and 10kVA silenced diesel
20kVA
Up to ~20kVA
Welfare cabins plus site tools, event catering
On request
25–30kVA
Up to ~25–30kVA
Larger cabins, three-phase plant, bigger event loads
On request
Larger site generators
100kVA and above
Construction compounds, standby power, infrastructure
Up to 100kVA and above, on request

For anything above about 10kVA, and wherever you need three-phase power or a connection to a building's supply, get in touch. Share a list of the equipment you’ll be running with our live chat team and we’ll help you choose the right size.

Always ask a qualified electrician to check your loads first if you need to connect a generator to a building’s supply.

Ask about larger generators

Fuel consumption and runtime

Fuel use depends on the generator model, the load, tank size, operating conditions and how long it runs. A generator at half load can run far longer than its rated runtime. The figures below are the published HSS DIY specifications:

Generator
Fuel
Tank
Max runtime
Approx. use at that load
Suitcase 1.6kVA
Unleaded petrol
4L
7h
~0.6L/h
Portable 2.6kVA
Unleaded petrol
3L
3h (¾ load)
~1.0L/h
Generator 4kVA
Unleaded petrol
3L
3h (over 3kVA)
~1.0L/h
6kVA silenced
Diesel / HVO
24L
16h
~1.5L/h
10kVA silenced
Diesel / HVO
15L
10h
~1.5L/h

Please note: fuel isn't included in the hire. You can buy white diesel or HVO separately, or add an approved container so you can buy petrol from your local station.

For longer runtimes, connect a diesel generator to a bunded diesel fuel bowser (feed and return points, 500L road-tow), or refuel from a 100L mobile bunded diesel tank.

Generators outside on a site

How much does it cost to hire a generator?

The hire price depends on the generator's capacity and model, how long you hire it for, whether you need delivery, and any extra equipment. A small petrol generator starts from £28.76* inc. VAT. The 10kVA silenced diesel starts from £121.34* inc. VAT. For your exact rate, open a product and enter your dates and postcode. Damage Waiver is optional, at 16% of the hire charges.

*Prices checked November 2026, shown inc. VAT. Check live generator pages for current prices.

Check Hire Price · Generator hire costs explained

Generator delivery and collection

Choose your hire dates on the product page to check availability at your local HSS DIY branch. The petrol generators fit in an estate car, but the 6kVA and 10kVA diesels (195kg and 365kg) need at least a 7.5-tonne vehicle, so most customers have those delivered.

Delivery is priced by postcode and equipment size. Orders placed before 4:30pm on a weekday usually arrive within 24–48 hours, and same-day delivery may be available for orders placed before 9am. You can extend or end a hire from your HSS DIY account.

Check Availability · Find a branch

Generator safety

Generators are simple to use, but fuel, exhaust fumes and electricity all need care, so follow these points every time you run one:

  • Outdoors only: generator exhaust contains carbon monoxide. Never run a generator indoors or in a garage, shed or other enclosed space. Place it outside, well away from doors, windows and vents so fumes can't be drawn into a building, and point the exhaust away from people.
  • Fuel: refuel only when the generator is off and cool. Store fuel in approved containers, away from the unit.
  • Electrical: use 110V for site tools where possible, use RCD protection and undamaged leads, and never connect to a building's wiring without a qualified electrician.
  • Conditions: put the generator on level, dry ground and keep it out of rain and standing water unless the model is designed for it.
  • Instructions: follow the manufacturer's operating guide that comes with every HSS DIY hire.

Useful extras: RCD breakers and extension leads · transformers · 3-phase junction boxes and cables · all power hire

Industrial generators available to hire from HSS

Generator hire FAQs

How much does it cost to hire a generator per day?

Prices start from £28.76* inc. VAT for a 2.6kVA petrol generator and £121.34* inc. VAT for the 10kVA silenced diesel. Enter one-day dates on the product page for an exact daily rate.

*Prices checked 14 October 2026, shown inc. VAT. Check live generator pages for current prices.

What size generator do I need?

Add up the running load (kVA) of everything you'll use at the same time, allow for starting loads, add 20–25% headroom, and match the voltage. The size check above does this for you.

What can a 20kVA generator run?

Up to around 20kVA of combined load. For all-day running, aim to keep it to about 15–16kVA. That's typically a welfare cabin plus site tools and lighting, or event catering, depending on the actual loads and starting currents. Contact HSS about 20kVA and larger generators.

How much fuel does a generator use?

It depends on the model and the load. For example, the 6kVA diesel uses around 1.5L per hour (16 hours on 24L), and the 2.6kVA petrol about 1L per hour at ¾ load.

How long can a generator run continuously?

From 3 to 16 hours per tank across the online range. For longer running, connect a diesel generator to a fuel bowser, and refuel only when it's off and cool.

Can HSS DIY deliver a generator?

Yes we can. Delivery is priced by postcode and usually takes 24–48 hours, and same-day delivery may be available if you order before 9am. You can also choose click and collect, just make sure your vehicle is big enough to transport the generator.

Hire a generator from HSS DIY today

Hiring a generator from us couldn’t be simpler. Once you know your load and voltage, you can book online in a few minutes. Here's how hiring a generator from HSS DIY works:

  1. Choose your generator. Compare continuous output, voltage and runtime in the listings above, or use the size check if you're not sure what you need.
  2. Enter your dates and postcode. You'll see the exact hire price, local availability and any delivery charge before you pay.
  3. Add the extras you need. These include extension leads, RCD breakers, transformers, 3-phase junction boxes, a petrol can or a fuel bowser. Damage Waiver is optional, at 16% of the hire charges.
  4. Collect or have it delivered. Click and collect from your local HSS DIY partner branch, often within an hour, or choose delivery, usually within 24–48 hours. Same-day delivery may be available for orders placed before 9am.
  5. Extend or end your hire online. Change your dates in your HSS DIY account or through live chat.

Before you book

  • Fuel: fuel isn't included in your hire. Petrol models need unleaded in an approved container, and diesel models need white diesel or HVO.
  • Transport: the petrol generators fit in an estate car. The 6kVA and 10kVA diesels need at least a 7.5-tonne vehicle, or delivery.
  • Insurance and deposit: you need your own plant hire insurance for the silenced diesels, and selected items require a deposit, shown at checkout.

Need help choosing? Our team can help you work out your load and pick the right generator. Use Live Chat. For 20kVA and larger generators, three-phase supplies or long-term site power, ask for a quote.

Buy the materials. Hire the tools. One order. All in one place.

Get DIY Happy with HSS DIY: The Home of Great Projects.

Meet the people behind our Tips & Advice

From quick fixes to bigger DIY projects, get to know the people behind the guides helping you get the job done with confidence.

→ Discover our authors


Related Products

Site information

  • Ecovadis Gold 2023 Accreditation
  • Ecovadis Platinum 2025 Accreditation
  • Advanced CHAS Accreditation
  • Hire Association Europe Accreditation

HSS ProService Ltd 2026. All rights reserved.

Company No. 11084154

Building 2, Think Park, Mosley Road, Trafford Park, Manchester, M17 1FQ

As a supplier of partially or fully rebated fuels HSS ProService is approved by HMRC as a registered dealer in controlled oil.